Breaker Testing


Power Factor Testing of Circuit Breakers

Detecting contamination and deterioration in SF6 breakers to ensure longevity BY LINDA NOWAK, Doble Engineering Company The purpose of “Doble testing”, or power factor testing, SF6 (sulfur hexafluoride) circuit breakers is to detect the presence of contamination and/or deterioration of the...

Vacuum Interrupter Testing for Circuit Breakers

How to predict field life using vacuum interrupters BY FINLEY LEDBETTER, Group CBS Utilities have widely replaced older air-magnetic and oil interrupters for circuit breakers rated at one kilovolt (kV) or higher with vacuum interrupters (VI) due to higher interrupt capability. Vacuum interrupters...

The Role of Thermal Imagining in Today’s Electrical Utilities Sector

In today’s society we are faced with many obstacles, one of these obstacles is the high cost of electricity around the world.  Electricity prices for commercial, industrial and institutional have increased a considerable amount.  There are many reasons why this is occurring, including the lack...

Breaker Testing

Circuit Breaker Time and Motion Testing

Determining mechanical condition of high-voltage circuit breakers

BY JOZEF LEVI, Doble Engineering Company

Life expectancy of a newly installed high-voltage circuit breaker is approximately 40 years. Throughout its life, under normal circuit conditions, the circuit breaker will operate less than ten minutes. During abnormal circuit conditions, the breaker will operate less than one minute in its lifetime.

The primary goal of circuit breaker testing is to determine the condition of the circuit breaker. Breakers have...

Related Articles


The Role of Thermal Imagining in Today’s Electrical Utilities Sector

In today’s society we are faced with many obstacles, one of these obstacles is the high cost of electricity around the world.  Electricity prices for commercial, industrial and institutional have increased a considerable amount.  There are many reasons why this is occurring, including the lack...

Dynamic Resistance Measurement

Condition testing of circuit breaker’s arcing contacts BY BUDO MILOVIC, DV-Power The preventive maintenance on a high-voltage (HV) breaker consists of several routine tests. The timing and motion tests are methods used to assess the breaker’s mechanical condition. When the timing and motion...

Circuit Breaker Lubrication

Developing circuit breaker lubrication procedures BY RICK YOUNGBLOOD, Doble Engineering Company Circuit breaker analyzers are used to determine operating speeds and velocity. This information enables the tester to determine if a breaker is safe to place back into service. The data recorded by a...


The Role of Thermal Imagining in Today’s Electrical Utilities Sector

In today’s society we are faced with many obstacles, one of these obstacles is the high cost of electricity around the world.  Electricity prices for commercial, industrial and institutional have increased a considerable amount.  There are many reasons why this is occurring, including the lack...

Partial Discharge & Circuit Breaker Asset Management

Detecting and avoiding preventable failures BY JAY GARNETT, Doble Engineering Company While metal clad switchgear can be very reliable, sometimes operating for over 50 years, throughout the aging process, this group of electrical disconnect switches, fuses and circuit breakers can experience issues...

Circuit Breaker Time and Motion Testing

Determining mechanical condition of high-voltage circuit breakers BY JOZEF LEVI, Doble Engineering Company Life expectancy of a newly installed high-voltage circuit breaker is approximately 40 years. Throughout its life, under normal circuit conditions, the circuit breaker will operate less than...

Circuit Breaker Lubrication

Developing circuit breaker lubrication procedures BY RICK YOUNGBLOOD, Doble Engineering Company Circuit breaker analyzers are used to determine operating speeds and velocity. This information enables the tester to determine if a breaker is safe to place back into service. The data recorded by a...

Power Factor Testing of Circuit Breakers

Detecting contamination and deterioration in SF6 breakers to ensure longevity BY LINDA NOWAK, Doble Engineering Company The purpose of “Doble testing”, or power factor testing, SF6 (sulfur hexafluoride) circuit breakers is to detect the presence of contamination and/or deterioration of the...