Breaker Testing
Vacuum Interrupter Testing for Circuit Breakers
Circuit Breaker Lubrication
Breaker Testing
Partial Discharge & Circuit Breaker Asset Management
Detecting and avoiding preventable failures
BY JAY GARNETT, Doble Engineering Company
While metal clad switchgear can be very reliable, sometimes operating for over 50 years, throughout the aging process, this group of electrical disconnect switches, fuses and circuit breakers can experience issues such as moisture ingress, animal intrusion, enclosure rusting, and insulation deterioration. One efficient approach to detect incipient failures is partial discharge (PD), a leading indicator of various failure modes. Using both acoustic and...
Related Articles
Circuit Breaker Lubrication
Developing circuit breaker lubrication procedures BY RICK YOUNGBLOOD, Doble Engineering Company Circuit breaker analyzers are used to determine operating speeds and velocity. This information enables the tester to determine if a breaker is safe to place back into service. The data recorded by a...
ACCELERATING TOWARDS GREATER TESTING EFFICIENCY - A true transformer test van
Test lead management, including quality of connection and correct lead placement, is an important part of testing. Poor or incorrect connections can be the culprit for nonrepresentative results that ultimately lead to longer test times and, in some cases, wasteful investigations to diagnose...
The Role of Thermal Imagining in Today’s Electrical Utilities Sector
In today’s society we are faced with many obstacles, one of these obstacles is the high cost of electricity around the world. Electricity prices for commercial, industrial and institutional have increased a considerable amount. There are many reasons why this is occurring, including the lack...
Dynamic Resistance Measurement
Condition testing of circuit breaker’s arcing contacts BY BUDO MILOVIC, DV-Power The preventive maintenance on a high-voltage (HV) breaker consists of several routine tests. The timing and motion tests are methods used to assess the breaker’s mechanical condition. When the timing and motion...
ACCELERATING TOWARDS GREATER TESTING EFFICIENCY - A true transformer test van
Test lead management, including quality of connection and correct lead placement, is an important part of testing. Poor or incorrect connections can be the culprit for nonrepresentative results that ultimately lead to longer test times and, in some cases, wasteful investigations to diagnose...
The Role of Thermal Imagining in Today’s Electrical Utilities Sector
In today’s society we are faced with many obstacles, one of these obstacles is the high cost of electricity around the world. Electricity prices for commercial, industrial and institutional have increased a considerable amount. There are many reasons why this is occurring, including the lack...
Partial Discharge & Circuit Breaker Asset Management
Detecting and avoiding preventable failures BY JAY GARNETT, Doble Engineering Company While metal clad switchgear can be very reliable, sometimes operating for over 50 years, throughout the aging process, this group of electrical disconnect switches, fuses and circuit breakers can experience issues...
Circuit Breaker Time and Motion Testing
Determining mechanical condition of high-voltage circuit breakers BY JOZEF LEVI, Doble Engineering Company Life expectancy of a newly installed high-voltage circuit breaker is approximately 40 years. Throughout its life, under normal circuit conditions, the circuit breaker will operate less than...
Circuit Breaker Lubrication
Developing circuit breaker lubrication procedures BY RICK YOUNGBLOOD, Doble Engineering Company Circuit breaker analyzers are used to determine operating speeds and velocity. This information enables the tester to determine if a breaker is safe to place back into service. The data recorded by a...
Power Factor Testing of Circuit Breakers
Detecting contamination and deterioration in SF6 breakers to ensure longevity BY LINDA NOWAK, Doble Engineering Company The purpose of “Doble testing”, or power factor testing, SF6 (sulfur hexafluoride) circuit breakers is to detect the presence of contamination and/or deterioration of the...